Zero Edge
3-1-24 Transcript
8-8-23
Outline Systems
Pool Zero Edge (Independent) - Total Perimeter 120’, Wind Conditions 10-12 MPH requires 3/8” meniscus
120 Inner Linear Ft. * 7 =
840 gpm
Circulation
28 gpm
Spa Spillover (Independent)
36 Outer Linear Ft. * 7 gpm =
252 gpm
Deck Jets and Bubblers (same system with (3) speeds programed with automation)
One speed for just Deck Jets
One speed for just Bubblers
One speed for both
Laminar Deck Jets (Independent)
3*10 gpm =
30 gpm
Has to be filtered
(3) Bubbler (Independent)
3*25 gpm =
75 gpm
How many Pumping Systems required?
840 / 240 = 3.5 - 4 pumps
Eliminated:
Water wall
Acrylic wall spillover
8-9-23
Finalize if we will have gas heater for spa
Determine if we need more than 100 amp panel
Calculate total gallons of fountain
Water Demands
Circulation modes: pool mode, spa mode
Homework
STA-RITE - (2) PDF’s
Use charts to size pipes for the (4) systems
Pick one system to do TDH calculations